Monolith系列耗材 —— 完美您的实验
NanoTemper 为 Monolith NT.115 系列,NT.LabelFree 和NT.Automated 专门设计的试剂盒和毛细管,助您取得高质量的 MST 实验数据。
NanoTemper 在制造 MST 实验专用的高性能毛细管方面积累了丰富的经验。毛细管通过最好的设施、最严格的工艺制造,其质量已经达到诊断级别。所有毛细管都是通过全自动的方式在洁净室里生产,经过严格的测试,以保证在质量和性能方面的最高级别。我们受专利保护的毛细管技术能够最高限度地降低对蛋白质的影响,这也是与NanoTemper 追求卓越品质的精神保持一致。
Monolith 系列耗材
The Monolith Anti Photobleach Kit is designed to eliminate fluorophore photobleaching.
D001 is recommended when setting up a new assay on a Monolith NT.115 series system.
D001 is recommended when setting up a new assay on a Monolith NT.115 series system.
This kit contains all capillaries, buffers and additives that are needed to setup an assay on the Monolith NT.115 series system. It also contains a detailed guideline how to obtain optimal results.
Content:
Only for use with Monolith NT.115 Series Instruments
D002 is recommended when setting up a new assay on the NT.LabelFree system.
D002 is recommended when setting up a new assay on the NT.LabelFree system.
This kit contains all capillaries, buffers and additives that are needed to setup an assay on the Monolith NT.LabelFree system. It also contains a detailed guideline how to obtain optimal results.
Content:
Only for use with Monolith NT.LabelFree
The Monolith Anti Photobleach Kit is designed to eliminate fluorophore photobleaching.
D001 is recommended when setting up a new assay on a Monolith NT.115 series system.
D001 is recommended when setting up a new assay on a Monolith NT.115 series system.
This kit contains all capillaries, buffers and additives that are needed to setup an assay on the Monolith NT.115 series system. It also contains a detailed guideline how to obtain optimal results.
Content:
Only for use with Monolith NT.115 Series Instruments
D002 is recommended when setting up a new assay on the NT.LabelFree system.
D002 is recommended when setting up a new assay on the NT.LabelFree system.
This kit contains all capillaries, buffers and additives that are needed to setup an assay on the Monolith NT.LabelFree system. It also contains a detailed guideline how to obtain optimal results.
Content:
Only for use with Monolith NT.LabelFree
Molecular Interaction Control Kit for Monolith instruments with Nano - GREEN/RED, Nano - BLUE/RED or Pico - RED detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with Nano - GREEN/RED, Nano - BLUE/RED or Pico - RED detectors
Molecular Interaction Control Kit for Monolith instruments with Nano - GREEN/RED or Nano - BLUE/GREEN detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with Nano - GREEN/RED or Nano - BLUE/GREEN detectors
Control Kit for Monolith instruments with LabelFree detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with LabelFree detectors
Molecular Interaction Control Kit for Monolith instruments with Nano - GREEN/RED, Nano - BLUE/RED or Pico - RED detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with Nano - GREEN/RED, Nano - BLUE/RED or Pico - RED detectors
Molecular Interaction Control Kit for Monolith instruments with Nano - GREEN/RED or Nano - BLUE/GREEN detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with Nano - GREEN/RED or Nano - BLUE/GREEN detectors
Control Kit for Monolith instruments with LabelFree detectors
Monolith™ Control Kits contain biomolecules and a protocol for performing standard biomolecular interaction experiments using Monolith instruments. Monolith Control Kits are recommended
Only for Monolith instruments with LabelFree detectors
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-647
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive NHS-ester group that modyfies primary amines as they are present in amino acids like lysine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channels of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-495
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive NHS-ester group that modyfies primary amines as they are present in amino acids like lysine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-BLUE channel of Monolith NT.115 Blue/Red and Blue/Green, and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-647
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive maleimide group that modyfies the amino acid cysteine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channel of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
Kit for 30 min labeling of His-tagged proteins with the dye NT-647
The Monolith His-tag Labeling Kit provides convenient means for the site-specific, purification-free labeling of small amounts of His-tagged proteins with our NT647 fluorescence dye. This kit can be used for the labeling of any protein or peptide carrying a polyhistidine-tag (His-tag) and contains everything required to perform labeling for 500 single-point MST measurements. Labeling can be completed in 30 min, no removal of excess dye is required.
The dye is suited for the Nano-RED channel of Monolith NT.115 GREEN/RED or BLUE/RED and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-647
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive NHS-ester group that modyfies primary amines as they are present in amino acids like lysine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channels of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-547
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive NHS-ester group that modyfies primary amines as they are present in amino acids like lysine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-GREEN channel of Monolith NT.115 Green/Red and Blue/Green, and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-495
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive NHS-ester group that modyfies primary amines as they are present in amino acids like lysine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-BLUE channel of Monolith NT.115 Blue/Red and Blue/Green, and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-647
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive maleimide group that modyfies the amino acid cysteine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channel of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
Detection of binding-induced conformational changes by SAW
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive maleimide group that modyfies the amino acid cysteine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channel of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
Kit for 1h labeling and purification of 4x 100 µg protein with the dye NT-495
Monolith™ Protein Labeling Kits contain labeling and purification reagents as well as protocols optimized for use with MicroScale Thermophoresis (MST). The dye carries a reactive maleimide group that modyfies the amino acid cysteine. Proteins with a MW of more than 5 kDa are efficiently labeled with this kit.
The dye is suited for the Nano-RED and Pico-RED channel of Monolith NT.115 Green/Red and Blue/Red, Monolith NT.115Pico and Monolith NT.Automated instruments.
NEW: Kit for site-specific labeling of Antibodies with the dye NT-647
The Monolith™ Antibody Labeling Kit RED-MALEIMIDE is designed to label antibodies with our established NT-647 dye. This kit contains labeling and purification reagents as well as a protocol optimized for antibodies and their use with MicroScale Thermophoresis (MST).
The dye is suited for the Nano-RED and Pico-RED channels of Monolith NT.115 GREEN/RED or BLUE/RED, Monolith NT.115Pico and Monolith NT.Automated instruments.
Download the Application Note and learn how this kit helps you with your antibody research projects.
Kit for 30 min labeling of His-tagged proteins with the dye NT-647
The Monolith His-tag Labeling Kit provides convenient means for the site-specific, purification-free labeling of small amounts of His-tagged proteins with our NT647 fluorescence dye. This kit can be used for the labeling of any protein or peptide carrying a polyhistidine-tag (His-tag) and contains everything required to perform labeling for 500 single-point MST measurements. Labeling can be completed in 30 min, no removal of excess dye is required.
The dye is suited for the Nano-RED channel of Monolith NT.115 GREEN/RED or BLUE/RED and Monolith NT.Automated instruments.
High precision capillary geometry, physically treated to obtain high quality surface properties.
1000 Standard Treated Capillaries for the NT.115 Series instrument. This is the standard type of capillary used for most assays on the NT.115 Series instruments. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.115 Series instruments
High precision capillary geometry, covalently coated with a specially designed polymer to prevent surface adsorption of molecules.
200 Capillaries for the NT.115 Series instrument. This capillary type is used for samples that tend to adsorb to surfaces. The surface is covalently coated with a dense brush of a specially designed polymer. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.115 Series instruments
High precision capillary geometry, physically treated to obtain high quality surface properties.
1000 Standard Treated Capillaries for the NT.115 Series instrument. This is the standard type of capillary used for most assays on the NT.115 Series instruments. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.115 Series instruments
High precision capillary geometry, covalently coated with a hydrophobic polymer to prevent surface adsorption of molecules.
200 Capillaries for the NT.115 Series instrument. This capillary type is used for samples that tend to adsorb to surfaces. The surface is covalently coated with a dense brush of a hydrophobic polymer. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.115 Series instruments
High precision capillary geometry, covalently coated with a specially designed polymer to prevent surface adsorption of molecules.
200 Capillaries for the NT.115 Series instrument. This capillary type is used for samples that tend to adsorb to surfaces. The surface is covalently coated with a dense brush of a specially designed polymer. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.115 Series instruments
High precision capillary geometry, physically treated to obtain high quality surface properties and low background signal.
200 Zero Background Standard Treated Capillaries for the NT.LabelFree instrument. This is the standard type of capillary used for most assays on the NT.LabelFree instrument. The capillaries are optimized for MST measurements; the exceptional reproducibility allow you to get high quality MST data. The quality of the material suppresses auto-fluorescence and background fluctuation.
Content:
Only for use with NT.LabelFree
High precision capillary geometry, covalently coated with a hydrophobic polymer to prevent surface adsorption of molecules.
200 Zero Background Capillaries for the NT.LabelFree instrument. This capillary type is used for samples that show an adsorbtion to surfaces. The surface of the capillary is covalently coated with a dense brush of a hydrophobic polymer. The capillaries are optimized for MST measurements; the exceptional reproducibility allow you to get high quality MST data. The quality of the material suppresses auto-fluorescence and background fluctuation.
Content:
Only for use with NT.LabelFree
High precision capillary geometry, covalently coated with a specially designed polymer to prevent surface adsorption of molecules.
200 Capillaries for the NT.LabelFree instrument. This capillary type is used for samples that tend to adsorb to surfaces. The surface is covalently coated with a dense brush of a specially designed polymer. The capillaries are optimized for MST measurements; the exceptional reproducibility and glass purity allow you to get high quality MST data.
Content:
Only for use with Monolith NT.LabelFree
Premium Capillary Tray for NT.115 and NT.115Pico
Premium Capillary Tray for NT.LabelFree
Facilitates manual filling of capillary chips